Title: Environmental influences contributing to window failure of the SLAC 50 MW klystron

Technical Report ·
DOI:https://doi.org/10.2172/5033188· OSTI ID:5033188

The additional heating of the klystron window is due to the intense x-ray level, produced inside the klystron, illuminating the entrance of the output wave guide. Photo-electric effect, although of low efficiency, produces enough electrons at the right location and right phase to start multipactor, which progresses with increasing intensity towards the window. The intercepted charge and the concomitant x-radiation heat the window, but the heating is not the cause of the breakdown per se. The accumulated charge on the window creates electric stress, which comes in addition to the RF stress. It could therefore be a major cause of electrical breakdown. The coating, which is intended to carry this charge off, should have a relaxation time constant small compared to the pulse duration. Unfortunately the coating can not be made conducting enough because it conflicts with the Joule heating in the RF field.

Research Organization:
SLAC National Accelerator Lab., Menlo Park, CA (United States)
DOE Contract Number:
AC03-76SF00515
OSTI ID:
5033188
Report Number(s):
SLAC/AP-19; ON: DE84008972
Resource Relation:
Other Information: Portions are illegible in microfiche products