The NSLS VUV undulator: Spectral characteristics and operating experience
The design and operating characteristics of the VUV undulator installed on the NSLS VUV ring are presented. Specifically, the spectral output through three circular on-axis pinholes of different diameters has been measured. Near the minimum magnetic gap (40mm), the flux into a 0.25 mrad circular aperture at the peak of the fundamental (h..nu.. = 57 eV) is approx.1 /times/ 10/sup 14/ photonssec0.1A1%BW. We find good agreement in spectral shape between these measured spectra and spectra calculated by integrating the theoretical undulator emission spectrum over the relevant spatial variables and including electron beam emittance. We also show calculated zero-emittance and on-axis flux spectra for comparison. A description is given of the beam line and monochromator currently installed on this undulator for the purpose of performing spin-resolved photoemission.
- Research Organization:
- Brookhaven National Lab., Upton, NY (USA)
- DOE Contract Number:
- AC02-76CH00016
- OSTI ID:
- 5015978
- Report Number(s):
- BNL-41291; CONF-870610-24; CONF-870610-; ON: DE88010664
- Country of Publication:
- United States
- Language:
- English
Similar Records
Normal-incidence monochromator branch line on the FEL-Undulator for experimental studies in the 5 to 30 eV region
Soft-x-ray imaging with the 35 period undulator at the NSLS