Pilot scale evaluation of peroxone for treatment of contaminated groundwater
- USAE Waterways Experiment Station, Vicksburg, MS (United States). Environmental Lab.
- Rocky Mountain Arsenal, Commerce City, CO (United States). Office of Program Manager
Advance oxidation processes (AOPS) are treatment processes that rely on the hydroxyl radical to destroy contaminants in polluted waters. Peroxone is an advanced oxidation process that utilizes the reaction of ozone and hydrogen peroxide to produce hydroxyl radicals without the requirement of ultraviolet light. The USAE Waterways Experiment Station (WES) evaluated the use of peroxone at Rocky Mountain Arsenal (RMA) for treatment of groundwater contaminated with diisopropylmethylphosphonate (DIMP) and low levels of pesticides. This evaluation was performed at RMA using a pilot scale treatment system. Results indicate that DIMP was easily oxidized to below detection limit levels. Optimization of the process indicated that a 250 mg/l hydrogen peroxide dose in four columns plumbed in series that were all sparged with 2.2% ozonated air at a rate of 2.S scfm.
- OSTI ID:
- 49387
- Report Number(s):
- CONF-941189--; ISBN 1-56590-016-2
- Country of Publication:
- United States
- Language:
- English
Similar Records
Laboratory assessment of advanced oxidation processes for treatment of explosives and chlorinated solvents in groundwater from the former Nebraska ordnance plant. Final report
Disinfection of model indicator organisms in a drinking water pilot plant by using PEROXONE