Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Pilot scale evaluation of peroxone for treatment of contaminated groundwater

Conference ·
OSTI ID:49387
; ; ;  [1]; ;  [2]
  1. USAE Waterways Experiment Station, Vicksburg, MS (United States). Environmental Lab.
  2. Rocky Mountain Arsenal, Commerce City, CO (United States). Office of Program Manager

Advance oxidation processes (AOPS) are treatment processes that rely on the hydroxyl radical to destroy contaminants in polluted waters. Peroxone is an advanced oxidation process that utilizes the reaction of ozone and hydrogen peroxide to produce hydroxyl radicals without the requirement of ultraviolet light. The USAE Waterways Experiment Station (WES) evaluated the use of peroxone at Rocky Mountain Arsenal (RMA) for treatment of groundwater contaminated with diisopropylmethylphosphonate (DIMP) and low levels of pesticides. This evaluation was performed at RMA using a pilot scale treatment system. Results indicate that DIMP was easily oxidized to below detection limit levels. Optimization of the process indicated that a 250 mg/l hydrogen peroxide dose in four columns plumbed in series that were all sparged with 2.2% ozonated air at a rate of 2.S scfm.

OSTI ID:
49387
Report Number(s):
CONF-941189--; ISBN 1-56590-016-2
Country of Publication:
United States
Language:
English