An attempt is made to determine in an exact way the influence of two consecutive dead times of the extended type on the count rate if they are inserted into a sequence of pulses. The original process, which may be due to the decays of a radioactive source, is assumed to be of the Poisson type; it is shown that insertion of the first dead time results in increasing the count rate at the output rather than diminishing it. (FR)