Zinc Bromide Combustion: Implications for the Consolidated Incinerator Facility
In the nuclear industry, zinc bromide (ZnBr2) is used for radiation shielding. At Savannah River Site (SRS) zinc bromide solution, in appropriate configurations and housings, was used mainly for shielding in viewing windows in nuclear reactor and separation areas. Waste stream feeds that will be incinerated at the CIF will occasionally include zinc bromide solution/gel matrices.The CIF air pollution systems control uses a water-quench and steam atomizer scrubber that collects salts, ash and trace metals in the liquid phase. Water is re-circulated in the quench unit until a predetermined amount of suspended solids or dissolved salts are present. After reaching the threshold limit, "dirty liquid", also called "blowdown", is pumped to a storage tank in preparation for treatment and disposal. The air pollution control system is coupled to a HEPA pre-filter/filter unit, which removes particulate matter from the flue gas stream (1).The objective of this report is to review existing literature data on the stability of zinc bromide (ZnBr2) at CIF operating temperatures (>870 degrees C (1600 degrees F) and determine what the combustion products are in the presence of excess air. The partitioning of the combustion products among the quencher/scrubber solution, bottom ash and stack will also be evaluated. In this report, side reactions between zinc bromide and its combustion products with fuel oil were not taken into consideration.
- Research Organization:
- Savannah River Site
- Sponsoring Organization:
- DOE
- DOE Contract Number:
- AC09-96SR18500
- OSTI ID:
- 4881
- Report Number(s):
- WSRC-RP-98-01266; ON: DE00004881
- Country of Publication:
- United States
- Language:
- English
Similar Records
Dynamic simulation study of the Consolidated Incineration Facility (CIF) incinerator at the Savannah River Site
Operation of a 1/10 scale mixed water incinerator air pollution control system
The Savannah River Plant Consolidated Incineration Facility
Conference
·
Tue Dec 31 23:00:00 EST 1991
·
OSTI ID:5182823
Operation of a 1/10 scale mixed water incinerator air pollution control system
Conference
·
Thu Aug 01 00:00:00 EDT 1996
·
OSTI ID:270699
The Savannah River Plant Consolidated Incineration Facility
Conference
·
Wed Dec 31 23:00:00 EST 1986
·
OSTI ID:6501662