CONOSEAL GASKET CREVICE CORROSION STUDY CVTR PROJECT. Terminal Report

Technical Report ·
OSTI ID:4843563
Zircaloy-2 to AISI type 410 gasketed joints were corrosion tested in simulated CVTR coolant water for periods up to 180 days at 300 and 567 deg F. Special emphasis was placed on testing for possible crevice corrosion effects. Neither serious general corrosion nor pitting was observed on the test specimens. (auth)
Research Organization:
Westinghouse Electric Corp. Atomic Power Dept., Pittsburgh
NSA Number:
NSA-15-027990
OSTI ID:
4843563
Report Number(s):
CVNA-87
Country of Publication:
United States
Language:
English

Similar Records

CVTR IN-PILE LOOP TEST. Terminal Report
Technical Report · Sat Sep 01 00:00:00 EDT 1962 · OSTI ID:4718513

CORROSION OF ZIRCALOY IN CREVICES UNDER NUCLEATE BOILING CONDITIONS
Technical Report · Thu Apr 12 23:00:00 EST 1962 · OSTI ID:4830227

EVALUATION OF CONTROL ROD MATERIALS CVTR PROJECT. Terminal Report
Technical Report · Thu Dec 31 23:00:00 EST 1959 · OSTI ID:4842785