A simple and rapid method was developed for measuring low concentrations of strontium-90 in milk, with an estimated standard deviation of 1 mu mu c per liter in the 1- to 20- mu mu c per liter range. A liter of milk is passed successively through cation exchange resin, to remove the alkaline and alkaline earth ions, and through anion exchange resin, which retains the yttrium-90 daughter of strontium90. The yttrium is eluted with dilute hydrochloric acid, precipitated as the oxalate, and counted in an anti-coincidence beta counter. Good agreement is found between this method and a previously established method. (auth)

Research Organization:
Southeastern Radiological Health Lab., Montgomery, Ala.
Sponsoring Organization:
USDOE
NSA Number:
NSA-15-029132
OSTI ID:
4842971
Journal Information:
Analytical Chemistry, Journal Name: Analytical Chemistry Journal Issue: 10 Vol. 33; ISSN 0003-2700
Publisher:
American Chemical Society (ACS)
Country of Publication:
Country unknown/Code not available
Language:
English

Similar Records

Improved Determination of Strontium-90 in Milk by an Ion Exchange Method
Journal Article · Sat Feb 29 23:00:00 EST 1964 · Analytical Chemistry · OSTI ID:4105184

STRONTIUM-90 BY AN ION EXCHANGE METHOD
Journal Article · Sat Feb 28 23:00:00 EST 1959 · Analytical Chemistry (U.S.) Formerly Ind. Eng. Chem., Anal. Ed. · OSTI ID:4288793

METHODS FOR THE DETERMINATION OF STRONTIUM-90
Journal Article · Wed Dec 31 23:00:00 EST 1958 · Revista Mexicana de Fisica (Mexico) · OSTI ID:4258907