Title: SPURIOUS SIGNALS IN A NUCLEAR REACTOR CONTROL SYSTEM AND TECHNICAL PROCEDURE FOR THEIR ELIMINATION (in Italian)

Journal Article · · Energia nucleare (Milan)
OSTI ID:4842316

Several types of troubles are discussed that appeared during two years of operation of the SORIN swimming-pool reactor, and the procedures followed for their elimination are outlined. The following types of spurious signals are described: radiofrequency interferences; mechanical instabilities in the cables carring low-level signals; voltage fluctuations and fast transients in the ion chamber power supplies; thermoelectric potentials in coaxial cables and connectors placed in strong neutron fields; and ohmic and magnetic inductions. (auth)

Research Organization:
SORIN, Centro Ricerche Nucleari, Saluggia, Italy
NSA Number:
NSA-15-027083
OSTI ID:
4842316
Journal Information:
Energia nucleare (Milan), Vol. Vol: 8; Other Information: Orig. Receipt Date: 31-DEC-61
Country of Publication:
Country unknown/Code not available
Language:
Italian