FAST NEUTRON DETECTION FOR TIME OF FLIGHT SPECTROMETRY. Final Report
Technical Report
·
OSTI ID:4837751
The development of a solid state neutron detector system with nanosecond response for use in neutron time-offlight measurements is described. The neutron energy range of interest is 0.5 to 10 Mev. A study of avalanche transistors was made, and R-C wide band amplifiers were designed and evaluated. (D.L.C.)
- Research Organization:
- Solid State Radiations, Inc., Los Angeles
- DOE Contract Number:
- W-7405-ENG-48
- NSA Number:
- NSA-15-030850
- OSTI ID:
- 4837751
- Report Number(s):
- UCRL-13009
- Resource Relation:
- Other Information: For Univ. of California Lawrence Radiation Lab., Livermore. Orig. Receipt Date: 31-DEC-61
- Country of Publication:
- United States
- Language:
- English