STRENGTH AND METALLURGICAL PROPERTIES OF THE ZIRCALOY-2 PRESSURE TUBES FOR THE PRTR
Technical Report
·
OSTI ID:4832166
The ultimate hoop strength of the annealed portion of the PRTR Zircaloy- 2 pressure tubes was determined by hydrostatic burst tests wherein the tube test specimens were internally pressurized to failure at temperatures from 425 to 750 deg F. In these tests, biaxial stresses simulating reactor operating conditions are imposed so that the circumferential stress is approximately twice the axial stress. The ultimate strength of the PRTR tubes thus tested is about 40 to 50% greater than the ultimate strength of rolled and annealed Zircaloy-2 strip determined from tensile tests. Extrapolation of long term (circa 5000 hours) tensile creep tests on longitudinal specimens cut from the annealed portion of the PRTR tubes showed that a stress of about 20000 psi will produce about 1% total deformation in ten years (the service limit used in the design of PRTR tubes) whereas for rolled strip Zircaloy-2 a stress of about 15000 psi would produce about 1% strain in ten years. These data further show that in tensite creep tests about 90% of the total creep deformation occurs during the primary creep stage. Very short term (circa 100 hours) pressure creep tests suggest that, under biaxial stress conditions (circumferential stress equal to twice the axial stress) the primary creep deformation is much less than was anticipated from an analysis of the uniaxial tests. Using the annealed ultimate strength, determined from hydrostatic burst tests and the PRTR operating conditions (1050 psig at 550 deg F), the safety factor is nearly 3.5 compared to a safety factor of 2.5 based on the ultimate strength of annealed Zircaloy-2 strip; for PRTR scram type trip limits (1160 psig at 550 deg F) the safety factors are respectively about 3 and 2. (auth)
- Research Organization:
- General Electric Co. Hanford Atomic Products Operation, Richland, Wash.
- DOE Contract Number:
- AT(45-1)-1350
- NSA Number:
- NSA-16-018034
- OSTI ID:
- 4832166
- Report Number(s):
- HW-73398
- Country of Publication:
- United States
- Language:
- English
Similar Records
INTERIM REPORT ON THE HYDROSTATIC DESTRUCTIVE TESTING OF ZIRCALOY-2 PRESSURE TUBING
ELEVATED TEMPERATURE CREEP PROPERTIES OF B120VCA SHEET MATERIAL. Period Covered July 1959-January 1960
PRTR SINGLE TUBE PROTOTYPE MOCKUP (STPM) OPERATIONAL CHARACTERISTICS
Technical Report
·
Thu Oct 15 00:00:00 EDT 1959
·
OSTI ID:4221839
ELEVATED TEMPERATURE CREEP PROPERTIES OF B120VCA SHEET MATERIAL. Period Covered July 1959-January 1960
Technical Report
·
Sun May 01 00:00:00 EDT 1960
·
OSTI ID:4058915
PRTR SINGLE TUBE PROTOTYPE MOCKUP (STPM) OPERATIONAL CHARACTERISTICS
Technical Report
·
Wed Jul 01 00:00:00 EDT 1959
·
OSTI ID:4071281