Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

"CRUD" SCRUBBING WITH A PUREX-TYPE ZEBRA CARTRIDGE

Technical Report ·
OSTI ID:4827752

To investigate the possibility of crud entrainment limiting decontamination factors in the Purex solvent extraction process, pilot plant tests were made in a glass column containing Zebra scrub and nozzle plate extraction section cartridges. The crud was simulated by dispersion of precipitated MnO/sub 2/ in the organic phase, and an interfacial crud was formed when the organic phase was contacted with the aqueous scrub. The results indicate that Zebra dispersion removes the crud from the organic phase, but that talc or bentonite is necessary in order that the crud would be flushed out of the scrub section by the HAS flow. Other possible benefits of the talc are given. (D.L.C.)

Research Organization:
General Electric Co. Hanford Atomic Products Operation, Richland, Wash.
DOE Contract Number:
AT(45-1)-1350
NSA Number:
NSA-16-004218
OSTI ID:
4827752
Report Number(s):
HW-63791(Rev.1)
Country of Publication:
United States
Language:
English

Similar Records

ORGANIC CONTINUOUS CARTRIDGE FOR THE PUREX 2D COLUMN
Technical Report · Thu Aug 16 00:00:00 EDT 1956 · OSTI ID:4153952

Crud formation in the Purex and Thorex processes
Journal Article · Sun Nov 30 23:00:00 EST 1986 · Nucl. Technol.; (United States) · OSTI ID:7094985

PUREX PULSE COLUMN STUDIES-1960