ANALYTICAL METHOD FOR THE DETERMINATION OF HYDRAZINE IN FEED AND BOILER WATERS

Technical Report ·
OSTI ID:4827599
A sample of the cooled water is mixed with paradimethylaminobenzaldehyde dissolved in acidified alcohol. The intensity of the yellow color produced is measured with an absorptiometer. The method is suitable for the direct determlnation of hydrazine (0 to 0.3 ppm) in the feed and boiler waters at Calder Works. lt is not suitable for colored waters or those containing suspended matter. (auth)