Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

DESIGN OF A LINEAR, INDUCTION, ELECTROMAGNETIC PUMP

Technical Report ·
OSTI ID:4827240

A linear induction electromagnetic pump was designed for use as the Hallam Nuclear Power Facility sodium service pumps. The design requirements are 100 gpm at 35 psi pressure rise for 650 deg F sodium, ambient temperature of 200 deg F, and gamma radiation fields of 5 x10/sup 5/ r/hr. (D.L.C.)

Research Organization:
Atomics International. Div. of North American Aviation, Inc., Canoga Park, Calif.
DOE Contract Number:
AT(11-1)-GEN-8
NSA Number:
NSA-16-004243
OSTI ID:
4827240
Report Number(s):
NAA-SR-Memo-5184(Rev.B)
Country of Publication:
United States
Language:
English

Similar Records

DESIGN OF TWO ELECTROMAGNETIC PUMPS FOR NaK
Technical Report · Thu Mar 24 23:00:00 EST 1960 · OSTI ID:4159743

A LINEAR INDUCTION PUMP FOR LIQUID METALS
Technical Report · Thu Jan 14 23:00:00 EST 1960 · OSTI ID:4186996

Weights and Efficiencies of Helical-Rotor Electromagnetic Pumps for Sodium Service