Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

DETERMINATION OF URANIUM IN THE 310 STAINLESS STEEL RIBBON-TYPE FUEL ELEMENT BY THE APPLICATION OF THE MERCURY CATHODE-LEAD REDUCTOR-CERIC SULFATE METHOD

Technical Report ·
OSTI ID:4822114
The mercury cathode --lead reductor --potassium dichromate method previously used for the determination of uranium in 310 stainless steel ribbon- type fuel elements was improved. The sample is dissolved in perchloric acid, electrolyzed in a mercury cathode cell, and reduced by a lead reductor. The resulting tetravalent uranium is then titrated with standard ceric sulfate, using ferroin as the indicator. By employing this method, the over-all time of analysis was reduced by approximately four hours, and the precision of the determination was increased from a standard deviation of 0.055% to a standard deviation of 0.029% uranium dioxide. (auth)
Research Organization:
General Electric Co. Aircraft Nuclear Propulsion Dept., Cincinnati
DOE Contract Number:
AT(11-1)-171
NSA Number:
NSA-16-005264
OSTI ID:
4822114
Report Number(s):
APEX-170
Country of Publication:
United States
Language:
English