ROLE OF THE PACKING IN A SCHEIBEL EXTRACTOR
Journal Article
·
· Ind. Eng. Chem., Process Design Develop.
OSTI ID:4816455
Drop size in a Scheibel extractor is determined by drop size in the mixing sections, Very little change in average drop size takes place in the packing. The amount of extraction in Yorkmesh packing was measured by using a sampling technique developed to obtain point concentrations of both streams inside the column. Drop size and hold-up in a Scheibel column at constant stirrer speed closely paralleled that of a packed column. Stirrer speed had a marked effect on transfer area and concentration gradient in the packed sections. The magnitude of these effects was determined for the methyl isobutyl ketone-- acetic acid-- water system in a four-stage Scheibel extractor. (auth)
- Research Organization:
- Iowa State Univ., Ames
- NSA Number:
- NSA-16-020547
- OSTI ID:
- 4816455
- Report Number(s):
- IS-202
- Journal Information:
- Ind. Eng. Chem., Process Design Develop. , Journal Name: Ind. Eng. Chem., Process Design Develop. Vol. Vol: 1
- Country of Publication:
- Country unknown/Code not available
- Language:
- English
Similar Records
PULSE COLUMN DESIGN
LIQUID-LIQUID EXTRACTION. PART XI. MASS TRANSFER DATA FOR THE EXTRACTION OF URANYL NITRATE IN A PACKED COLUMN
Simultaneous determination of trace amounts of chromium, cobalt and lead in waste water and plant materials by extraction -- atomic absorption spectrometry
Technical Report
·
Fri Oct 31 23:00:00 EST 1958
·
OSTI ID:4230417
LIQUID-LIQUID EXTRACTION. PART XI. MASS TRANSFER DATA FOR THE EXTRACTION OF URANYL NITRATE IN A PACKED COLUMN
Journal Article
·
Thu Aug 01 00:00:00 EDT 1957
· Trans. Inst. Chem. Engrs. (London)
·
OSTI ID:4349945
Simultaneous determination of trace amounts of chromium, cobalt and lead in waste water and plant materials by extraction -- atomic absorption spectrometry
Journal Article
·
Tue Mar 31 23:00:00 EST 1998
· Analytical Letters
·
OSTI ID:638292