An improved miniature-ion-chamber system for measuring neutron fluxes in the Dresden reactor is described. The array of miniature ion chambers provides a detailed picture of the distribution of power within the reactor core, enabling the operator to avoid local hot spots and optimize over-all core performance. The system continuously monitors the neutron flux within the core of the reactor. The system is composed of l6 detector assemblies, each containing four axially displaced fission ehambers positioned in 16 modified fuel bundles dispersed radially in the core for optimum coverage. The sensitivity average of the system is 3.7 x 10-/sup -18/ amp per n/cm/sup 2//sec. Response begins at 1% of rated power and covers a range of 5 x 10/sup 11/ to 10/sup 14/ n/cm/sup 2//sec. Initially, over-all system accuracy is estimated at approximately 10% in thermal power as indicated by the control-room meter for a full-scale reading of 280,000 Btu/hr-ft/sup 2/. (N.W.R.)
Research Organization:
General Electric Co., San Jose, Calif.
NSA Number:
NSA-16-008944
OSTI ID:
4816451
Journal Information:
Nucleonics (U.S.) Ceased publication, Journal Name: Nucleonics (U.S.) Ceased publication Vol. Vol: 20: No. 2; ISSN NUCLA
Country of Publication:
Country unknown/Code not available
Language:
English

Similar Records

A COMPENSATED IONIZATION CHAMBER FOR THE MEASUREMENT OF THE THERMAL NEUTRON FLUX
Journal Article · Sat Oct 01 00:00:00 EDT 1960 · Kerntechnik (West Germany) Merged with Atomkernenergie to form Atomkernenerg./Kerntech.kyu Hokoku · OSTI ID:4113422

TWO IONISATION CHAMBERS FOR ACTIVITY MEASUREMENTS ON WIRES USED FOR NEUTRON- FLUX SCANNING
Technical Report · Mon Sep 01 00:00:00 EDT 1958 · OSTI ID:4307175

HFIR PRELIMINARY PHYSICS REPORT
Technical Report · Tue Oct 18 20:00:00 EDT 1960 · OSTI ID:4123862