Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

THE POWER OUTPUT AND EFFICIENCY OF THERMIONIC CONVERTERS CONNECTED IN SERIES AND PARALLEL CIRCUITS--PART I

Technical Report ·
DOI:https://doi.org/10.2172/4814368· OSTI ID:4814368

Optimum and off-optimum performance is experimentally obtained for one of the 10 mil spaced, 7 cm/sup 2/ emitter area, cylindrical geometry thermionic converters to be used in the series and parallel connected thermionic converter experiment. The results are presented as graphs of output voltage vs power input, and power output vs power input. The current is the major parameter in both cases. The data in these forms are used to compute the power output of twin converter circults having unequal power inputs. The optimum load conditions for operation are then determined. The results are valuable in guiding thermionic power plant design. (auth)

Research Organization:
Atomics International. Div. of north American Aviation, Inc., Canoga Park, Calif.
DOE Contract Number:
AT(11-1)-GEN-8
NSA Number:
NSA-16-025908
OSTI ID:
4814368
Report Number(s):
NAA-SR-Memo-7278
Country of Publication:
United States
Language:
English

Similar Records

Design of series-parallel connected thermionic converter arrays
Conference · Wed Dec 31 23:00:00 EST 1980 · Proc., Intersoc. Energy Convers. Eng. Conf.; (United States) · OSTI ID:6790826

PERFORMANCE OF CESIUM THERMIONIC DIODES OPERATED IN SERIES-PARALLEL CIRCUITS
Technical Report · Thu Jan 31 23:00:00 EST 1963 · OSTI ID:4726743

PERFORMANCE OF CESIUM THERMIONIC DIODES OPERATED IN SERIES-PARALLEL CIRCUITS