The shot peening of the outer surface of Alloy 800 is proposed by the steam generator supplier in order to increase the stress corrosion cracking resistance of the tubes. The benefits and drawbacks of such a treatment are evaluated, focusing on the main concern i.e. a possible enhanced tendency of stress corrosion cracking at the transition of the expanded tube-to-tubesheet joint. Stress corrosion tests as well as residual stresses measurements demonstrate no significant difference between peened and unpeened tubes at that location. The other concerns such as stability of the compressive stresses, increased risk of pitting or intergranular attack and pollution of the secondary circuit by fragmented beads appear the as minor concerns.
- OSTI ID:
- 48126
- Report Number(s):
- CONF-910808--
- Country of Publication:
- United States
- Language:
- English
Similar Records
Shot peening to prevent the corrosion cracking of austenitic stainless steels
The effect of shot peening on transition SCC of Alloy 600 steam generator tubing
Production of intergranular attack of alloy 600, alloy 690, and alloy 800 tubing in tubesheet crevices: Topical report
Journal Article
·
Fri Jun 01 00:00:00 EDT 1979
· J. Mater. Energy Syst.; (United States)
·
OSTI ID:6199541
The effect of shot peening on transition SCC of Alloy 600 steam generator tubing
Conference
·
Wed Dec 31 23:00:00 EST 1986
·
OSTI ID:7079016
Production of intergranular attack of alloy 600, alloy 690, and alloy 800 tubing in tubesheet crevices: Topical report
Technical Report
·
Wed Jul 01 00:00:00 EDT 1987
·
OSTI ID:6129549