Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

SINGLE ELEMENT FLOW TESTS FOR TYPE 3 (SM-2) FUEL ELEMENTS IN SM-1, SM-1A, AND PM-2A CORES

Technical Report ·
DOI:https://doi.org/10.2172/4804440· OSTI ID:4804440
Channel-to-channel flow distribution within Type 3 (SM-2, stationary and control rod fuel elements modified for use in the SM-1, SM1-1A, and PM-2A core support structures and control rod tubes was measured in single element flow testing. Plots of channel-to-channel flow distribution and element pressure drop at various element flow rates are given. Flow distribution for the top-orificed SM-1A and PM-2A stationary elements was within the plus or minus 12% deviation from element average utilized in previous thermal analyses of these cores. Testing of the bottom-orificed SM-1 stationary element and the SM-1, SM-1A, and PM-2A control rod assemblies showed flow distribution exceeded plus or minus 12% devation from average. Simple modifications to the SM-1 stationary element indicated the possibility of improvng fiow distribution in that element. (auth)
Research Organization:
Alco Products. Inc., Schenectady, N.Y.
NSA Number:
NSA-16-006087
OSTI ID:
4804440
Report Number(s):
APAE-Memo-297
Country of Publication:
United States
Language:
English