INVESTIGATION OF THE TECHNICAL FEASIBILITY OF COLD EXTRUSION FOR ZIRCALOY-2 TUBING PRODUCTION. Quarterly Technical Progress Report, July-September, 1961
Bar-extrusion tests were performed at 50. 65, and 80% reductions at room temperature and 300 deg C. Tensile tests were conducted on as-extruded and heat-treated specimens. The results are tabulated for comparison. The extrusion of small tubing, 0.560-in. OD x 0.030-in. wall, in the first and second tube- extrusion steps are described. (B.O.G.)