THE RECOVERY AND PURIFICATION OF MULTI-KILOCURIE QUANTITIES OF FISSION PRODUCT STRONTIUM BY CATION EXCHANGE
In seven production runs, 75,000 curies of Sr/sup 90/ were isolated and purified in the ion-exchange equipment of Hanford Laboratories High Level Cells. The production goal (60,000 curies of purified Sr/sup 90/) and the time schedule were met or exceeded and the product exceeded the customer's purity requirements. The hot-cell-purified strontium made possible the completion on time of the Weather Bureau power source and the Martin 10 watt SNAP VII-A and VIl-C units. The isotopic purity of the strontium product was 56% Sr/sup 90/. The chemical purity was greater than 95% strontium. The Zr-Nb/sup 95/ contamination of the product was less than 5 x 10/sup -5/ curies per curie of Sr/sup 90/, and the Ce- Pr contamination was less than 1 x 10/sup -5/ curies per curie of Sr/sup 90/. The final run yielded 16,500 curies of Sr/sup 90/ in an eight liter product solution. The product was >98% strontium and contained less than one curie of Zr- Nb/sup 90/ or Ce-Pr/sup 144/. Eleven days of continuous operation were required to complete the run. (auth)
- Research Organization:
- General Electric Co. Hanford Atomic Products Operation, Richland, Wash.
- DOE Contract Number:
- AT(45-1)-1350
- NSA Number:
- NSA-16-008805
- OSTI ID:
- 4800556
- Report Number(s):
- HW-70998
- Country of Publication:
- United States
- Language:
- English
Similar Records
STUDIES ON SOLVENT EXTRACTION USING RADIOACTIVE ISOTOPES. IX. SOLVENT EXTRACTION OF CARRIER-FREE CERIUM-144 WITH ACETYLACETONE
SOLVENT EXTRACTION RECOVERY AND PURIFICATION OF STRONTIUM-90
DETERMINATION OF RADIOSTRONTIUM BY ION EXCHANGE
Journal Article
·
Wed Jan 31 23:00:00 EST 1962
· Bull. Chem. Soc. Japan
·
OSTI ID:4827440
SOLVENT EXTRACTION RECOVERY AND PURIFICATION OF STRONTIUM-90
Technical Report
·
Tue Dec 12 23:00:00 EST 1961
·
OSTI ID:4752532
DETERMINATION OF RADIOSTRONTIUM BY ION EXCHANGE
Technical Report
·
Thu Jun 15 00:00:00 EDT 1961
·
OSTI ID:4840949