Starting performance of high-frequency electronic ballasts for four-foot fluorescent lamps
Journal Article
·
· IEEE Transactions on Industry Applications
- Rensselaer Polytechnic Inst., Troy, NY (United States). Lighting Research Center
With the rapidly increasing number of electronic ballast manufacturers and ballast products entering the market recently, the compatibility of fluorescent lamps with electronic ballasts has become one of the major concerns among specifiers and users. In 1993, the American National Standards Institute (ANSI) published ANSI C82.11-1993, which describes recommendations for high-frequency operation of fluorescent lamp ballasts. To address compatibility issues for lamp starting, ANSI C82.11 limits the average value of the rms glow current to a maximum of 25 mA and lamp preheat time to a minimum of 500 ms. The ANSI`s definitions of glow current and preheat time are made on an ideal lamp starting curve. In reality, some electronic ballasts produce lamp starting curves very different from ANSI`s definition, creating difficulties in practical measurements of glow current and preheat time. This research work tested lamp starting characteristics of 17 different electronic ballasts on 2-F40T12 lamps. The results showed that the starting performance of electronic ballasts varied; some met ANSI`s requirements, but some did not. The results also showed that using electrode voltage can better define preheat time and glow current, which can better characterize the starting performance of electronic ballasts and ensure reliable testing procedures.
- OSTI ID:
- 479407
- Journal Information:
- IEEE Transactions on Industry Applications, Journal Name: IEEE Transactions on Industry Applications Journal Issue: 1 Vol. 33; ISSN 0093-9994; ISSN ITIACR
- Country of Publication:
- United States
- Language:
- English
Similar Records
Starting performance of high-frequency electronic ballasts for 4-foot fluorescent lamps
Compatibility testing of fluorescent lamp and ballast systems
Does low ballast factor instant start operation reduce fluorescent lamp life?
Book
·
Sat Dec 30 23:00:00 EST 1995
·
OSTI ID:427906
Compatibility testing of fluorescent lamp and ballast systems
Journal Article
·
Tue Nov 30 23:00:00 EST 1999
· IEEE Transactions on Industry Applications (Institute of Electrical and Electronics Engineers)
·
OSTI ID:20014665
Does low ballast factor instant start operation reduce fluorescent lamp life?
Book
·
Thu Dec 30 23:00:00 EST 1993
·
OSTI ID:55541