Co-firing switchgrass in a 50 MW pulverized coal boiler
Conference
·
OSTI ID:478627
- Univ. of Wiconsin, Madison, WI (United States)
- Madison Gas and Electric Co., Madison, WI (United States)
Switchgrass is being co-fired with pulverized coal in a 50 MW wall-fired, radiant boiler at MG&E`s Blount Street generating station. Shredded switchgrass is fed to a hammermill onto a live bottom storage bunker. Twin screw augers move the switchgrass onto a belt conveyor which leads to a rotary air lock valve and through a pressurized pipe to the boiler where it is injected into the furnace at two points between first and second level coal burners. The main objective of the project is to evaluate the boiler performance, slagging behavior, and emissions of the co-fired switchgrass at replacement of rates of up to 20% by mass (13% by heat input). Initial co-firing tests to examine fuel handling and feeding, combustion behavior, boiler response and emissions are favorable. In November a 100 hour co-fire test is planned.
- OSTI ID:
- 478627
- Report Number(s):
- CONF-960958--
- Country of Publication:
- United States
- Language:
- English
Similar Records
Co-firing switchgrass in a 50 MW pulverized coal boiler
Co-firing of asphalt fired dust in pulverized coal fired boiler
Low NO{sub x} burner modifications to front-fired pulverized coal boilers
Conference
·
Mon Sep 01 00:00:00 EDT 1997
·
OSTI ID:514888
Co-firing of asphalt fired dust in pulverized coal fired boiler
Conference
·
Thu Jul 01 00:00:00 EDT 1999
·
OSTI ID:20006852
Low NO{sub x} burner modifications to front-fired pulverized coal boilers
Conference
·
Wed Jul 01 00:00:00 EDT 1998
·
OSTI ID:20050931