THE $gamma$-RAY PERFORMANCE OF A LARGE VOLUME PLASTIC SCINTILLATOR
Journal Article
·
· Nuclear Instr. & Methods
The gamma -ray spectral spread and the background count of a large plastic scintillator (20'' x 10'' x 61/2'') viewed by two 7" diameter photomultipliers (20th Century VMP/11/170 or E.M.I. 9623) were investigated. The spectral spread on the high energy side was compounded of three independent factors: (1) Statistical, (2) Geometrical, (3) Intrinsic, and contribution of each factor to the total spread was calculated from experimental gamma -ray spectra. The first two factors were then independently estimated (1) by determining the average number of photoelectrons released by a known energy deposition in the scintillator, and (2) by directing collimated beams of gamma - rays (from Cs/sup 137/ source) into the scintillator. It was found that the optimum performance could be obtained by applying proper distribution of high voltage on the photomultiplier and by using short light guides. The background spectra (0--3 Mev gamma -ray energy) was obtained inside a steel cubicle (5" thick wall) and additional 1" lead shielding reduced the background by 25%. The radioactivity of the photomultiplier and its contribution to the total background were measured. The perspex light guide (1" or 11/2" thick) reduced the background by about 10% which was due to the photomultiplier radioactivity. The photomultiplier noise which determines the lowest measurable energy was found to be an increasing function with the voltage between photocathode and first dynode. Finally, the two types of 7" photomultipliers (VMP/11/170 and 9623) showed almost the same performances at their best conditions. (auth)
- Research Organization:
- Univ. of Leeds, Eng.
- NSA Number:
- NSA-17-003326
- OSTI ID:
- 4764615
- Journal Information:
- Nuclear Instr. & Methods, Journal Name: Nuclear Instr. & Methods Vol. Vol: 16
- Country of Publication:
- Country unknown/Code not available
- Language:
- English
Similar Records
Operating Characteristics of Large Diameter Photomultipliers I. Scintillation-Spectrometric Performance
OPERATING CHARACTERISTICS OF LARGE DIAMETER PHOTOMULTIPLIERS. II. NOISE
Method and apparatus for measurement of radioactivity over an extended range
Journal Article
·
Sat Jun 01 00:00:00 EDT 1963
· Japanese Journal of Applied Physics
·
OSTI ID:4691286
OPERATING CHARACTERISTICS OF LARGE DIAMETER PHOTOMULTIPLIERS. II. NOISE
Journal Article
·
Tue Oct 01 00:00:00 EDT 1963
· Japan J. Appl. Phys.
·
OSTI ID:4143620
Method and apparatus for measurement of radioactivity over an extended range
Patent
·
Mon Dec 22 23:00:00 EST 1986
·
OSTI ID:6853381