THE USE OF ION EXCHANGE COLUMNS IN THE MEASUREMENT OF DOSES BELOW 1000 RAD WITH THE FRICKE DOSIMETER

Journal Article · · Intern. J. Appl. Radiation Isotopes
ABS>The use of Fe/sup 59/ as tracer in the solution of the Fricke dosimeter for low doses is discussed. Solvent extraction as a means of separating the ferric ions from the ferrous ions involves considerable error, and it was found that a zirconium phosphate ion-exchange column simplified the separation. Ferrous ions are eluted with 0.1N H/sub 2/SO/sub 4/, while ferric ions are retained on the column but may be eluted with 6N HCl. A dosimetric procedure using Fe/sup 59/ and ionexchange separation is outlined; it was found suitable for measuring doses from 1000 to 40 rad, and the lower limit is 10 to 20 rad. (D.L.C.)
Research Organization:
Boris Kidric Inst., Vintcha, Yugoslavia
NSA Number:
NSA-17-006453
OSTI ID:
4763955
Journal Information:
Intern. J. Appl. Radiation Isotopes, Journal Name: Intern. J. Appl. Radiation Isotopes Vol. Vol: 13
Country of Publication:
Country unknown/Code not available
Language:
English

Similar Records

Absorbed gamma radiation dose in the Fricke dosimeter
Journal Article · Wed Dec 31 23:00:00 EST 1980 · Annu. Book ASTM Stand.; (United States) · OSTI ID:5549850

Study of the absorption spectra of Fricke Xylenol Orange gel dosimeters
Conference · Wed Jul 01 00:00:00 EDT 2015 · OSTI ID:22531276

ENERGY DEPOSITION BY FAST NEUTRONS. II. YIELD OF THE FRICKE DOSIMETER AT 14.6 Mev
Technical Report · Mon Dec 31 23:00:00 EST 1962 · OSTI ID:4089696