ENRICO FERMI ATOMIC POWER PLANT REVISED LICENSE APPLICATION. PART B, VOL. 8. PROPOSED TECHNICAL SPECIFICATIONS. PART I. OPERATION AT LEVELS IN EXCESS OF ONE MEGAWATT. PART II. OPERATION AT LEVELS NOT IN EXCESS OF 200 MEGAWATTS (PRELIMINARY DRAFT)

Technical Report ·
OSTI ID:4759613
Technical specifications are presented to establish limitations (1 and 200 Mw) beyond which the facility is not to operate. The site, containment, primary sodium coolant system, primary plant auxiliary systems, secondary sodium coolant system, steam and feedwater system, emergency cooling systems, reactor core and blanket, control and safety systems, monitoring systems, waste disposal systems, fuel storage facilities, administrative organization and safeguards, experimental facilities, initial reactor loading, and program of operations are considered. (M.C.G.)
Research Organization:
Power Reactor Development Co., Detroit
NSA Number:
NSA-17-004301
OSTI ID:
4759613
Report Number(s):
NP-10458(Vol.8)
Country of Publication:
Country unknown/Code not available
Language:
English