FILM CAPABILITIES FOR HIGH LEVEL DOSE EVALUATION
Technical Report
·
OSTI ID:4749401
An investigation was conducted to determine the highlevel dose measuring capabilities of the duPont 558 film packet containing 508-sensitive and 1290- insensitive film emulsions. The accuracy of the film processing system was also evaluated. It was found that for statistically sound high-level dose determinations, the characteristic response curves of 1290 film limits the sensitivity of the beta-gamma film badge dosimeter to an upper limit of about 1500 r. A summary of density and spectrographic measurements on these film emulsions was included. (J.R.D.)
- Research Organization:
- General Electric Co. Hanford Atomic Products Operation, Richland, Wash.
- DOE Contract Number:
- AT(45-1)-1350
- NSA Number:
- NSA-17-014646
- OSTI ID:
- 4749401
- Report Number(s):
- HW-71133
- Country of Publication:
- United States
- Language:
- English