ANALYTICAL METHOD FOR THE CONVERSION OF MISCELLANEOUS URANIC MATERIALS (OTHER THAN URANIUM METAL) TO URANIUM OXIDE FOR SPECTROGRAPHIC PURPOSES

Technical Report ·
OSTI ID:4748207
Procedures for the preparative treatmert required for a variety of uranic compounds prior to spectrographic examination for impurity elements are described. To provide complete analytical procedures, the method must be used in conjunction with the following analytical methods: the spectrographic analysis of uranium metal by the carrier distillation method: the spectrographic determination of aluminium in U/sub 3/O/sub 8/; and the spectrographic determination of calcium in uranium metal. The method covers the treatment of uranium dioxide in powder or pellet form, uranium tetrafluoride, uranyl fluoride, uranyl nitrate solution, ammonium diuranate, and the solution arising from the hydrolysis of uranium hexafluoride. (auth)
Research Organization:
United Kingdom Atomic Energy Authority. Production Group, Springfields, Lancs, England
NSA Number:
NSA-17-015880
OSTI ID:
4748207
Report Number(s):
PG-Report-393
Country of Publication:
Country unknown/Code not available
Language:
English