Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

STANDARDIZATION OF Co$sup 60$ SOURCES BY /cap beta/-$gamma$ COINCIDENCE METHODS (in Rumanian)

Journal Article · · Acad. Rep. Populare Romine, Studii Cercetari Fiz.
OSTI ID:4729615
A method perfected for the standardization of Co/sup 60/ sources by using G-M counters is proposed. The manner of measuring correctly the gamma background in the counter which measures the BETA radiation is indicated and nurnerous corrections are made. (tr-auth)
Research Organization:
Inst. of Atomic Physics, Bucharest
NSA Number:
NSA-17-014320
OSTI ID:
4729615
Journal Information:
Acad. Rep. Populare Romine, Studii Cercetari Fiz., Journal Name: Acad. Rep. Populare Romine, Studii Cercetari Fiz. Vol. Vol: 13
Country of Publication:
Country unknown/Code not available
Language:
Rumanian

Similar Records

Correction for the Gamma-Ray Sensitivity of the Beta-Counter in the Standardization of Cobalt-60 by the Beta–Gamma Coincidence Method
Journal Article · Fri Feb 07 23:00:00 EST 1958 · Nature (London) · OSTI ID:4333729

HIGH PRECISION 4 $pi$$beta$-$gamma$-COINCIDENCE COUNTING AND THE PREPARATION OF SOLID Co$sup 60$ STANDARD SOURCES AND SOLUTIONS FOR AN INTERNATIONAL COMPARISON
Technical Report · Tue Dec 31 23:00:00 EST 1963 · OSTI ID:4081665

BETA-GAMMA DIRECTIONAL CORRELATION IN THE DECAY OF Co$sup 60$ AND Na$sup 2$$sup 2$
Journal Article · Mon Mar 14 23:00:00 EST 1960 · Physical Review (U.S.) Superseded in part by Phys. Rev. A, Phys. Rev. B: Solid State, Phys. Rev. C, and Phys. Rev. D · OSTI ID:4141143