Studies were made to determine coolant flow distribution to the core components, excluding fuel assemblies. The calculated coolant flow that by- passes the fuel elements is 39,275 lb/hr. The sources are: moderator coolant annuli, control rods, small experimental tubes, fuel-channel gas seal leakage, excess flow for fuel unloading, and excess flow for servicing operations. It was concluded that no coolant flow is required for flux scanner tubes or graphite plugs in large experimental loop channels. It was calculated that coolant leakage is negligible past ring seals in large experimental loop channels and gaps between graphite column and support plate at small experimental loop locations. (M.C.G.)
Research Organization:
Allis-Chalmers Mfg. Co. Atomic Energy Div., Washington, D.C.
NSA Number:
NSA-17-017568
OSTI ID:
4719387
Report Number(s):
TID-18248; EGCR-STUDY-II-179-1
Country of Publication:
United States
Language:
English

Similar Records

TEMPERATURE DISTRIBUTION MODERATOR AND REFLECTOR REACTOR CORE. EXPERIMENTAL GAS COOLED REACTOR
Technical Report · Mon Apr 25 00:00:00 EDT 1960 · OSTI ID:4719545

THE TEMPERATURE PATTERN IN DOUBLE FLOW-THROUGH REACTOR COOLANT CHANNELS
Journal Article · Tue Sep 01 00:00:00 EDT 1959 · Atomkernenergie (West Germany) Merged with Kerntechnik to form Atomkernenerg./Kerntech. Acta Radiol. Changed to Acta Radiol.: Oncol., Radiat. Phys. · OSTI ID:4222577

TEMPERATURE DISTRIBUTION, MODERATOR AND REFLECTOR REACTOR CORE
Technical Report · Tue Dec 20 23:00:00 EST 1960 · OSTI ID:4748590