Evaluation of continuous air monitor placement in a plutonium facility

Journal Article · · Health Physics
; ;  [1]
  1. Los Alamos National Lab., NM (United States); and others
Department of Energy appraisers found continuous air monitors at Department of Energy plutonium facilities alarmed less than 30% of the time when integrated room plutonium air concentrations exceeded 500 DAC-hours. Without other interventions, this alarm percentage suggests the possibility that workers could be exposed to high airborne concentrations without continuous air monitor alarms. Past research has shown that placement of continuous air monitors is a critical component in rapid and reliable detection of airborne releases. At Los Alamos National Laboratory and many other Department of Energy plutonium facilities, continuous air monitors have been primarily placed at ventilation exhaust points. The purpose of this study was to evaluate and compare the effectiveness of exhaust register placement of workplace continuous air monitors with other sampling locations. Polydisperse oil aerosols were released from multiple locations in two plutonium laboratories at Los Alamos National Laboratory. An array of laser particle counters positioned in the rooms measured time-resolved aerosol dispersion. Results showed alternative placement of air samplers generally resulted in aerosol detection that was faster, often more sensitive, and equally reliable compared with samplers at exhaust registers. 20 refs., 7 figs., 1 tab.
Sponsoring Organization:
USDOE
OSTI ID:
471483
Journal Information:
Health Physics, Journal Name: Health Physics Journal Issue: 5 Vol. 72; ISSN HLTPAO; ISSN 0017-9078
Country of Publication:
United States
Language:
English

Similar Records

Assessment of need for transport tubes when continuously monitoring for radioactive aerosols
Journal Article · Wed Sep 01 00:00:00 EDT 1999 · Health Physics · OSTI ID:20000250

CAM correlation to fixed air sample data at Los Alamos National Laboratory
Conference · Thu Dec 30 23:00:00 EST 1993 · OSTI ID:45329

Continuous air monitor correlation to fixed air sample data at Los Alamos National Laboratory