Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Comparison of neutron lifetimes as predicted by MCNP and DANTSYS

Conference ·
OSTI ID:471376
The prompt removal lifetime algorithm used in the latest version of MCNP was modified to conform with the neutron-balance definitions described by Spriggs et al. In accordance with the neutron-balance theory, the non-adjoint-weighted removal lifetime is given by where {Phi} is the angular neutron flux, v is the neutron velocity, {Sigma}{sub a} is the macroscopic absorption cross section, E is neutron energy, {Omega} is angle, and r is a spatial vector. The numerator in this expression represents the total neutron population in the system, N, and the denominator represents the total loss rate due to leakage and absorption.
Research Organization:
Los Alamos National Lab., NM (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
W-7405-ENG-36
OSTI ID:
471376
Report Number(s):
LA-UR--97-285; CONF-970607--16; ON: DE97004783
Country of Publication:
United States
Language:
English

Similar Records

KENO lifetimes
Conference · Wed Jan 29 23:00:00 EST 1997 · OSTI ID:471352

Definition of Neutron Lifespan and Neutron Lifetime in MCNP4B
Conference · Tue Jan 14 23:00:00 EST 1997 · OSTI ID:471370

Reactivity impact of delayed neutron spectra on MCNP calculations