EVALUATION OF A REDUCED PRESSURE BACKFLOW PREVENTER USING ACTIVATION ANALYSIS

Technical Report ·
DOI:https://doi.org/10.2172/4710469· OSTI ID:4710469
Despite its advantages of economy and convenience, the reduced-pressure- principle backflow preventer was oniy partialiy accepted as a substitutr for air- gap separation in preventing pollution of potable winter. To evaluate the protection provided by a reduced pressure principle backflow preventer, a unit was tested under the following static conditions; ionic diffusion, lower pressure on the supply side than on the discharge side, vacuum on the supply side, water hammer on the supply side, and water hammer on the discharge side. Using a solution of Mn and K nitrates as a nonradioactive tracer, backflow from the discharge side to the supply side was not detectable by activation and radiochemical analyses having a sensitivity of approximates 0.2 ppb Mn. The protection factor for the device is defined as: P. F. = (Reagent concentration in the discharge zone/ Reagent concentration in the supply zone due to backflow). The minimum protection factor proved in these tests based upon the limit of the sensitivity of Mn analysis is 6.5 x 10/sup 8/. This factor provides a rational basis for inatallation where the concentration of radioactivity or other contaminant can be estimated, measured, or limited. The K analyses also showed no detection of backflow but with a lesser sensitivity. (auth)
Research Organization:
Oak Ridge National Lab., Tenn.
DOE Contract Number:
W-7405-ENG-26
NSA Number:
NSA-17-010515
OSTI ID:
4710469
Report Number(s):
ORNL-3380
Country of Publication:
United States
Language:
English

Similar Records

Cross-connection control and backflow prevention
Conference · Wed Apr 25 23:00:00 EST 1984 · OSTI ID:6820718

Method for preventing bitumen backflow in injection wells when steam injection is interrupted
Patent · Tue Apr 24 00:00:00 EDT 1990 · OSTI ID:6557021

Backflow prevention and responsibilities of HVAC professionals
Journal Article · Sun Sep 01 00:00:00 EDT 1996 · Heating, Piping and Air Conditioning · OSTI ID:417975