INVESTIGATION OF LIQUID METAL BOILING HEAT TRANSFER. Quarterly Progress Report No. 4

Technical Report ·
OSTI ID:4697915
The high-flux nucleate pool boiler was subjected to preliminary check- out procedures during which water was pool boiled at fluxes from 20,000 to 500,000 Btu/(hr)(sq ft). The results checked well with previous data from a 3/8- in.OD tube. Thermocouple failures in the boiling tube produced a temporary delay. Construction of the film boiler was essentially completed. The liquid metal loop was received. Installation procedures were almost completed. The agravic studies were set back by a series of delays in the design and construction stages. Analytical studies of the film-boiling process have progressed. Preliminary results from this study are discussed, and calculated minimum fluxes for several alkali metals are tabulated. (auth)
Research Organization:
Michigan. Univ., Ann Arbor. Coll. of Engineering
NSA Number:
NSA-17-020172
OSTI ID:
4697915
Report Number(s):
NP-12699; ORA-04526-14-P
Country of Publication:
United States
Language:
English