Transportable vitrification system pilot demonstration with surrogate Oak Ridge WETF sludge

Technical Report ·
DOI:https://doi.org/10.2172/468530· OSTI ID:468530

Surrogate Oak Ridge Reservation West End Treatment Facility (WETF) sludge was vitrified in a pilot-scale EnVitCo melter at the Clemson University Environmental Systems Engineering Department (ESED) Vitrification Facility. Although much smaller than the Transportable Vitrification System (TVS) melter, this melter is similar in design to the one in the TVS. The TVS was built by EnVitCo for the Savannah River Technology Center (SRTC) for the treatment of low level and mixed wastes. A total of three tests were done by ESED personnel with guidance from SRTC TVS personnel. The purpose of these tests was to determine what problems might occur during the vitrification of WETF sludge feed in the TVS. The demonstration was successfully completed and the glasses produced passed the TCLP tests for all the hazardous waste components (Ba, Cd, Cr, Pb, and Ni). An overview of these tests and experimental results on glass container testing, glass pouring, glass product characterization, electrode and refractory wear, and offgas composition and particulate measurements will be given.

Research Organization:
Westinghouse Savannah River Co., Aiken, SC (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC09-89SR18035
OSTI ID:
468530
Report Number(s):
WSRC-MS--96-0338; CONF-970321--9; ON: DE97004893
Country of Publication:
United States
Language:
English