PULSE COUNTING PERIOD METER OUTPUT DURING STARTUP TRANSIENTS

Technical Report ·
OSTI ID:4682241
The time response of a period meter whose input signal comes from a pulse-counting channel is calculated using a Ferranti Mercury autocode program. The period meter considered is the type for which the logarithmic characteristic is approximated by several diode pump circuits. The input excitation is a terminated ramp of reactivity. Other reactivity inputs may be treated. In particular the step change of reactivity may be used as the input excitation. Allowance is made for the effective time constants of the diode pump circuits and the period meter. The program may be used for instrument assessment and for safety and operations studies on reactors which use this type of period meter. An example of the use of the program is given. (auth)
Research Organization:
United Kingdom Atomic Energy Authority. Reactor Group. Atomic Energy Establishment, Winfrith, Dorset, England
NSA Number:
NSA-17-024612
OSTI ID:
4682241
Report Number(s):
AEEW-R-245
Country of Publication:
United Kingdom
Language:
English

Similar Records

PERIOD METER OUTPUT DURING STARTUP TRANSIENTS
Technical Report · Wed Oct 31 23:00:00 EST 1962 · OSTI ID:4716997

OUTPUT OF THE TYPE 4051 AND 4061 PERIOD METERS DURING STARTUP TRANSIENTS
Technical Report · Wed May 01 00:00:00 EDT 1963 · OSTI ID:4165211

LOGARITHMIC RATE METERS AND THE PERIOD METERS. A THEORETICAL STUDY OF NOISE AND TRANSIENT RESPONSE
Journal Article · Sun Oct 01 00:00:00 EDT 1961 · Nuclear Sci. and Eng. · OSTI ID:4823287