Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Tests show best corrosion inhibitors for high pressure, temperature pipeline

Journal Article · · Oil and Gas Journal
OSTI ID:467787
 [1]; ;  [2];  [3]
  1. Texaco Inc., Bellaire, TX (United States)
  2. CLI International Inc., Houston, TX (United States)
  3. Texaco North Sea U.K. Co., London (United Kingdom)

Autoclave tests have determined corrosion-inhibitor effectiveness under the severe flow conditions anticipated for a pipeline to serve Texaco North Sea UK Co.`s Erskine field, the North Sea`s first high pressure, high-temperature field. The tests evaluated the inhibitors` performances over extended time and under varying conditions of flow-induced wall shear stress and closely simulated Erskine pipeline environment. The performances of these two inhibitors were determined on both conventional X-65 and a new 0.5% Cr-enhanced X-65 and a new 0.5% Cr-enhanced X-65 steel at inhibitor doses of 100 and 250 ppm. Data were measured for static, laminar, and impingement flow conditions at varying levels of flow-induced wall shear stress directly simulating anticipated Erskine pipeline operating conditions. Texaco North Sea will use the North Sea`s larger insulated pipeline (16 in. OD), corrosion-resistant alloy tubulars and flow lines, and several other innovative techniques to tap the Erskine field. Erskine`s reservoir conditions approach 14,000 psi and 340 F, with well-head pressures of 10,600 psi.

OSTI ID:
467787
Journal Information:
Oil and Gas Journal, Journal Name: Oil and Gas Journal Journal Issue: 18 Vol. 95; ISSN OIGJAV; ISSN 0030-1388
Country of Publication:
United States
Language:
English