Rupture Loop Annex (RLA) ion exchange vault entry and characterization
This engineering report documents the entry and characterization of the Rupture Loop Annex Ion Exchange (RLAIX) Vault located near the 309 Building`s Plutonium Recycle Test Reactor (PRTR). Twelve ion exchange columns were found in the vault. Some of which contained transuranics, Cs 137, and Co 60. The characterization information is necessary for future vault cleanout and column disposal.
- Research Organization:
- Westinghouse Hanford Co., Richland, WA (United States)
- Sponsoring Organization:
- USDOE Office of Environmental Restoration and Waste Management, Washington, DC (United States)
- DOE Contract Number:
- AC06-96RL13200
- OSTI ID:
- 464297
- Report Number(s):
- WHC-SD-NEL-ER--002; ON: DE97052149
- Country of Publication:
- United States
- Language:
- English
Similar Records
Rupture loop annex ion exchange RLAIX vault deactivation
PRTR ion exchange vault column sampling
Dose consequence analysis for transporting Plutonium Recycle Test Reactor (PRTR) rupture loop ion exchange columns
Technical Report
·
Thu Aug 01 00:00:00 EDT 1996
·
OSTI ID:659228
PRTR ion exchange vault column sampling
Technical Report
·
Mon Mar 13 23:00:00 EST 1995
·
OSTI ID:34340
Dose consequence analysis for transporting Plutonium Recycle Test Reactor (PRTR) rupture loop ion exchange columns
Technical Report
·
Wed Jul 03 00:00:00 EDT 1996
·
OSTI ID:663124