Rupture Loop Annex (RLA) ion exchange vault entry and characterization

Technical Report ·
DOI:https://doi.org/10.2172/464297· OSTI ID:464297
This engineering report documents the entry and characterization of the Rupture Loop Annex Ion Exchange (RLAIX) Vault located near the 309 Building`s Plutonium Recycle Test Reactor (PRTR). Twelve ion exchange columns were found in the vault. Some of which contained transuranics, Cs 137, and Co 60. The characterization information is necessary for future vault cleanout and column disposal.
Research Organization:
Westinghouse Hanford Co., Richland, WA (United States)
Sponsoring Organization:
USDOE Office of Environmental Restoration and Waste Management, Washington, DC (United States)
DOE Contract Number:
AC06-96RL13200
OSTI ID:
464297
Report Number(s):
WHC-SD-NEL-ER--002; ON: DE97052149
Country of Publication:
United States