CONNECTICUT YANKEE ATOMIC POWER COMPANY NUCLEAR POWER PLANT--UNIT NUMBER ONE, HADDAM, CONNECTICUT. PRELIMINARY HAZARDS SUMMARY REPORT
Technical Report
·
OSTI ID:4629284
The information necessary to provide a basis for evaluating the safety of the Connecticut Yankee Atomic Power Plant is presented. A description is given of the site, containment, reactor design, steam supply systems, shielding, instrumentation and control, and secondary systems. The testing, operation, administration, and training programs are described briefly. Finally, accidents and potential hazards are considered, and the maximum credible accident and a hypothetical accident are analyzed. (D.L.C.)