Performance evaluation of PEFC stack

Technical Report ·
DOI:https://doi.org/10.2172/460309· OSTI ID:460309
;  [1];  [2]
  1. Kansai Electric Power Co., Inc., Nakoji Amagasaki (Japan)
  2. Fuji Electric Corp. Research & Development, Ltd., Nagasaka Yokosuka (Japan)

Polymer electrolyte fuel cells (PEFCs) have many advantages such as high current density, short start-up time and endurance for start-stop cycles. Making use of these advantages, Fuji Electric has been working with the Kansai Electric Power Co., Inc. to explore practical applications of PEFCs for an electric utility use. Since large-sized electrodes are required in the electric utility applications, we have fabricated 600cm{sup 2} membrane-electrode assemblies by using hot-press method. We have also designed a cell structure to realize a uniform reaction over the electrodes. The structure includes a properly-shaped gas flow channel, a temperature-gradient cooling system. Using the 600cm{sup 2} (25x24cm) electrodes, a 30-cell stack (5kW) were constructed and tested.

Research Organization:
Fuel Cell Seminar Organizing Committee (United States)
OSTI ID:
460309
Report Number(s):
CONF-961107--Absts.; ON: TI97001494
Country of Publication:
United States
Language:
English

Similar Records

Performance evaluation of 1 kw PEFC
Technical Report · Mon Dec 30 23:00:00 EST 1996 · OSTI ID:460227

An optimization study on PEFC drive electric vehicle
Technical Report · Mon Dec 30 23:00:00 EST 1996 · OSTI ID:460310

Development of small polymer electrolyte fuel cell stacks
Technical Report · Mon Dec 30 23:00:00 EST 1996 · OSTI ID:460304