CRITICAL HEAT FLUX FOR LARGE DIAMETER, INTERNALLY HEATED ANNULI IN FORCED CONVECTION BOILING AT 1000 PSIA. Topical Report No. 6
Technical Report
·
OSTI ID:4582689
- Research Organization:
- Columbia Univ., New York. Engineering Research Labs
- DOE Contract Number:
- AT(30-3)-187
- NSA Number:
- NSA-20-004105
- OSTI ID:
- 4582689
- Report Number(s):
- TID-22321
- Resource Relation:
- Other Information: Orig. Receipt Date: 31-DEC-66
- Country of Publication:
- United States
- Language:
- English
Similar Records
ADDITIONAL CRITICAL HEAT FLUX DATA FOR LARGE DIAMETER, INTERNALLY HEATED, ECCENTRIC ANNULI AT 1000 PSIA. Topical Report No. 8
CRITICAL HEAT FLUXES IN INTERNALLY HEATED ANNULI OF LARGE DIAMETER COOLED BY BOILING WATER AT 1000 PSIA.
CRITICAL HEAT FLUX IN LONG TUBES AT 1000 PSIA WITH AND WITHOUT SWIRL PROMOTERS. Topical Report No. 4
Technical Report
·
Fri Jan 21 00:00:00 EST 1966
·
OSTI ID:4582689
CRITICAL HEAT FLUXES IN INTERNALLY HEATED ANNULI OF LARGE DIAMETER COOLED BY BOILING WATER AT 1000 PSIA.
Journal Article
·
Tue Oct 31 00:00:00 EST 1967
· pp 86-97 of Proceedings of the Third International Heat Transfer Conference, Chicago, Illinois, August 7--12, 1966. Volume III. New York, American Institute of Chemical Engineers, 1966.
·
OSTI ID:4582689
+1 more
CRITICAL HEAT FLUX IN LONG TUBES AT 1000 PSIA WITH AND WITHOUT SWIRL PROMOTERS. Topical Report No. 4
Technical Report
·
Mon Feb 01 00:00:00 EST 1965
·
OSTI ID:4582689