Evaluation of the effects of patient arm attenuation in SPECT cardiac perfusion imaging

Journal Article · · IEEE Transactions on Nuclear Science
OSTI ID:458236
; ; ;  [1]
  1. Univ. of Massachusetts Medical Center, Worcester, MA (United States)
It was hypothesized that the use of attenuation correction could compensate for degradation in the uniformity of apparent localization of imaging agents seen in cardiac walls when patients are imaged with arms at their sides. Noise-free simulations of the digital MCAT phantom were employed to investigate this hypothesis. Four variations in camera size and collimation scheme were investigated. The authors observed that: (1) without attenuation correction, the arms had little additional influences on the uniformity of the heart for 180{degree} reconstructions and caused a small increase in nonuniformity for 360{degree} reconstructions, where the impact of both arms was included; (2) change in patient size had more of an impact on count uniformity than the presence of the arms, either with or without attenuation correction; (3) for a low number of iterations and large patient size, slightly better uniformity was obtained from parallel emission data than from fan-beam emission data, independent of whether parallel or fan-beam transmission data was used to reconstruct the attenuation maps; and (4) for all camera configurations, uniformity was improved with attenuation correction and, given sufficient number of iterations, it was compatible among different imaging geometry combinations. Thus, iterative algorithms can compensate for the additional attenuation imposed by larger patients or having the arms on the sides. When the arms are at the sides of the patient, however, a larger radius of rotation may be required, resulting in decreased spatial resolution.
OSTI ID:
458236
Report Number(s):
CONF-951073--
Journal Information:
IEEE Transactions on Nuclear Science, Journal Name: IEEE Transactions on Nuclear Science Journal Issue: 6Pt2 Vol. 43; ISSN 0018-9499; ISSN IETNAE
Country of Publication:
United States
Language:
English

Similar Records

Quantitative cardiac SPECT reconstruction with reduced image degradation due to patient anatomy
Conference · Wed Nov 30 23:00:00 EST 1994 · IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (United States) · OSTI ID:6705193

Reconstruction of truncated TCT and SPECT data from a right-angle dual-camera system for myocardial SPECT
Conference · Mon Dec 30 23:00:00 EST 1996 · OSTI ID:513268

The effect of truncation reduction in fan beam transmission for attenuation correction of cardiac SPECT
Journal Article · Thu Aug 01 00:00:00 EDT 1996 · IEEE Transactions on Nuclear Science · OSTI ID:379765