Xenon and Samarium Tables

Technical Report ·
DOI:https://doi.org/10.2172/4564733· OSTI ID:4564733
 [1]
  1. Du Pont de Nemours (E.I.) and Co., Aiken, SC (United States). Savannah River Lab.

Tables are presented for calculating the reactivity transients that result from 135Xe or 149Sm poisoning in any thermal reactor that employs 235U as the principal fissionable material. Xenon and samarium concentrations are given as a function of time in units of absorptions per fission neutron. Tables are also given for the change in reactivity held in xenon after step reductions in power. Thermal flux is expressed in units of megawatts from thermal fissions per kilogram of 235U. These tables cover a range of power from 0 to 500 MW/kg.