SUR LA MESURE ET L'ANALYSE DES RAYONNEMENTS DE HAUTE ENERGIE PAR DETECTEURS A ACTIVATION. APPLICATION A LA DOSIMETRIE. (Measurement and Analysis of High-Energy Radiation Through Activation Detectors. Application in Dosimetry). (in French)
Thesis/Dissertation
·
OSTI ID:4549316
- Research Organization:
- Commissariat a l'Energie Atomique, Saclay (France). Centre d'Etudes Nucleaires
- NSA Number:
- NSA-22-021356
- OSTI ID:
- 4549316
- Report Number(s):
- CEA-R--3376
- Country of Publication:
- France
- Language:
- French
Similar Records
MESURE ABSOLUE D'UN FLUX ETALON DE NEUTRONS THERMIQUES PAR ACTIVATION DE DETECTEURS D'OR. (Absolute Measurement of a Standard Thermal-Neutron Flux Using Gold-Detector Activation).
DOSAGE DU STRONTIUM TOTAL DANS LES VEGETAUX. COMPARAISON DE L'ANALYSE PAR ACTIVATION ET DE LA PHOTOMETRIE DE FLAMME. (Determination of Total Strontium in Vegetables. Comparison of Activation Analysis with Flame Photometry).
Identification $d$ ' electrons et application a la mesure de la section efficace de production du quark top avec le detecteur $D^0$ au TeVatron
Thesis/Dissertation
·
Sat Dec 31 23:00:00 EST 1966
·
OSTI ID:4342420
DOSAGE DU STRONTIUM TOTAL DANS LES VEGETAUX. COMPARAISON DE L'ANALYSE PAR ACTIVATION ET DE LA PHOTOMETRIE DE FLAMME. (Determination of Total Strontium in Vegetables. Comparison of Activation Analysis with Flame Photometry).
Thesis/Dissertation
·
Fri Dec 31 23:00:00 EST 1965
·
OSTI ID:4562086
Identification $d$ ' electrons et application a la mesure de la section efficace de production du quark top avec le detecteur $D^0$ au TeVatron
Thesis/Dissertation
·
Mon Mar 31 23:00:00 EST 2003
·
OSTI ID:1419230
Related Subjects
ACTIVATION
BORON 11
BORON ISOTOPES B-11/proton reactions (p
n) at 150 MeV to 3 GeV with
cross sections for
(E)
CROSS SECTIONS
DOSEMETERS
GEV RANGE
MEASUREMENT
MEV RANGE
MOCKUP
N26200* --Instrumentation--Radiation Dosimeters
NUMERICALS
PHANTOMS
PHANTOMS/proton dosimetry in tissue-equivalent
using activation detectors
PROTON BEAMS
PROTONS/dosimetry of 3-GeV
in tissue-equivalent phantoms using activation detectors
PROTONS/reactions (p
2pn) with sulfur-34 at 50 MeV to 3 GeV
cross sections for
(T)
PROTONS/reactions (p
n) with boron- 11 at 150 MeV to 3 GeV
cross sections for
(E)
RADIATION DETECTORS
ACTIVATION/use for dosimetry
method for
RADIATION DOSES
SULFUR 34
SULFUR ISOTOPES S-34/proton reactions (p
2pn) at 50 MeV to 3 GeV with
cross sections for
(T)
USES
BORON 11
BORON ISOTOPES B-11/proton reactions (p
n) at 150 MeV to 3 GeV with
cross sections for
(E)
CROSS SECTIONS
DOSEMETERS
GEV RANGE
MEASUREMENT
MEV RANGE
MOCKUP
N26200* --Instrumentation--Radiation Dosimeters
NUMERICALS
PHANTOMS
PHANTOMS/proton dosimetry in tissue-equivalent
using activation detectors
PROTON BEAMS
PROTONS/dosimetry of 3-GeV
in tissue-equivalent phantoms using activation detectors
PROTONS/reactions (p
2pn) with sulfur-34 at 50 MeV to 3 GeV
cross sections for
(T)
PROTONS/reactions (p
n) with boron- 11 at 150 MeV to 3 GeV
cross sections for
(E)
RADIATION DETECTORS
ACTIVATION/use for dosimetry
method for
RADIATION DOSES
SULFUR 34
SULFUR ISOTOPES S-34/proton reactions (p
2pn) at 50 MeV to 3 GeV with
cross sections for
(T)
USES