Advanced development of non-discoloring EVA-based PV encapsulants

Journal Article · · AIP Conference Proceedings
DOI:https://doi.org/10.1063/1.49395· OSTI ID:453341
; ; ;  [1]; ; ;  [2]
  1. Springborn Laboratories, Inc., One Springborn Center, Enfield, Connecticut 06082 (United States)
  2. University of Connecticut, Institute of Materials Science, Storrs, Connecticut 06269-3136 (United States)
The purpose of this investigation was to better define the problem of field yellowing of EVA-based PV encapsulant, through laboratory study of probable chemical mechanisms and the development of stabilization strategies for protecting EVA from discoloration. EVA from fielded modules was analyzed for vinyl acetate content, unsaturation, and additive levels. These test results were then compared to results from Xenon Arc Weather-Ometer aged glass/EVA/glass laminates made in the laboratory. Variables evaluated in Weather-Ometer aged laminates included ``standard-cure`` A9918P EVA, ``fast-cure`` 15295P EVA, low iron glass superstrate containing cerium oxide, and systematic elimination or addition of specific additives. Six significant findings were revealed: 1) Improved ``standard-cure`` and ``fast-cure`` type EVA encapsulants, formulations X9903P and X15303P, respectively, showed little or no yellowing after extended Weather-Ometer exposure; 2) The use of {open_quote}{open_quote}fast-cure{close_quote}{close_quote} EVA reduced discoloration when compared with {open_quote}{open_quote}standard-cure{close_quote}{close_quote} A9918P EVA; 3) Glass superstrate containing cerium oxide resulted in a reduced rate of EVA discoloration; 4) {open_quote}{open_quote}Fast-cure{close_quote}{close_quote} EVA used with glass superstrate containing cerium oxide showed no visible yellowing after 32 weeks in the Weather-Ometer{emdash}a period estimated to be roughly equivalent to 20{endash}30 years of exposure in the Southwest; 5) Severely discolored EVA samples from the field showed no measurable loss of acetate group and little detectable unsaturation; and 6) EVA encapsulant with a Tefzel cover exhibited no yellowing after extended Weather-Ometer exposure. {copyright} {ital 1996 American Institute of Physics.}
Sponsoring Organization:
USDOE
OSTI ID:
453341
Report Number(s):
CONF-9605265--
Journal Information:
AIP Conference Proceedings, Journal Name: AIP Conference Proceedings Journal Issue: 1 Vol. 353; ISSN APCPCS; ISSN 0094-243X
Country of Publication:
United States
Language:
English

Similar Records

Photovoltaic manufacturing technology (PVMaT). Semiannual subcontract report, March 31, 1994--September 30, 1994
Technical Report · Fri Mar 31 23:00:00 EST 1995 · OSTI ID:64201

Investigation into the causes of browning in EVA encapsulated flat plate PV modules
Book · Fri Dec 30 23:00:00 EST 1994 · OSTI ID:208207

Review of the photothermal stability of EVA pottants: Effects of formulation on the discoloration rate and mitigation methods
Journal Article · Sun Feb 28 23:00:00 EST 1999 · AIP Conference Proceedings · OSTI ID:357202