Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Humidity sorption due to deposited aerosol particles studied in situ outdoors on gold surfaces

Journal Article · · Journal of the Electrochemical Society
DOI:https://doi.org/10.1149/1.1837371· OSTI ID:452216
;  [1]
  1. Royal Inst. of Tech., Stockholm (Sweden)

Accumulation rates of deposited aerosol particles on an inert gold surface and the resulting humidity interactions were investigated in situ outdoors using an atmospheric corrosivity probe based on the quartz crystal microbalance technique. In six exposures in one rural and two urban sites the common behavior is that the gold surfaces undergo both irreversible mass increase and reversible mass changes. Irreversible mass increase is interpreted as a deposit mainly consisting of aerosol particles from the accumulation mode. The irreversible mass increase could be correlated to aerosol particle concentrations measured at the exposure sites. The reversible mass changes are mainly due to water sorption, which is influenced by deposited aerosol particles and varies with relative humidity. Upon closer analysis of the reversible mass changes, typical episodic cases are identified. An analogy between the humidity interaction of wetted metal surfaces and of aerosol particles explains the wetting characteristics of the surface. Time of wetness, defined by predetermined levels of temperature and relative humidity, is shown to severely underestimate the actual time period when a surface with aerosol particle deposits is wetted.

Sponsoring Organization:
USDOE
OSTI ID:
452216
Journal Information:
Journal of the Electrochemical Society, Journal Name: Journal of the Electrochemical Society Journal Issue: 1 Vol. 144; ISSN JESOAN; ISSN 0013-4651
Country of Publication:
United States
Language:
English

Similar Records

Quartz crystal microbalance for in-situ outdoor corrosivity studies
Conference · Wed Dec 30 23:00:00 EST 1998 · OSTI ID:350160

In situ weight gain rates on copper during outdoor exposures: Dependence on airborne pollutants and climatic parameters
Journal Article · Tue Dec 31 23:00:00 EST 1996 · Journal of the Electrochemical Society · OSTI ID:452217

A quartz crystal microbalance probe developed for outdoor in situ atmospheric corrosivity monitoring
Journal Article · Thu Feb 29 23:00:00 EST 1996 · Journal of the Electrochemical Society · OSTI ID:220863