We designed the radial neutron spectrometer using a new type DT neutron spectrometer base on a recoil proton counter-telescope technique aiming ion temperature measurement for the International Thermonuclear Experimental Reactor (ITER). The neutron spectrometer will be installed on the well collimated neutron beam line. A large area recoil proton emitter is placed parallel to the incident neutron beam and microchannel collimating plates are inserted between the radiator and the recoil proton detectors away from the neutron beam in order to limit the scattering angle of protons to the proton detectors. Here a very thin polyethylene film and a silicon surface barrier detector are employed as the radiator and proton detector, respectively. The energy resolution and detection efficiency are estimated to be 2.5{percent} and 1{times}10{sup {minus}5} countsneutron{sup {minus}1}m{sup 2}, respectively, for the DT neutron through Monte Carlo calculations. Five units of the spectrometers will be installed just outside the biological shield, will include a fan array using penetrations inside the bioshield and a precollimator in the horizontal port. The lifetime of the proton detectors is estimated to be about one year in the basic performance phase of ITER by neutron transport calculations using the Monte Carlo neutron and photon transport code (MCNP). {copyright} {ital 1997 American Institute of Physics.}
- OSTI ID:
- 451803
- Report Number(s):
- CONF-960543--
- Journal Information:
- Review of Scientific Instruments, Journal Name: Review of Scientific Instruments Journal Issue: 1 Vol. 68; ISSN 0034-6748; ISSN RSINAK
- Country of Publication:
- United States
- Language:
- English
Similar Records
Development of neutron measurement system for n{sub d}/n{sub t} fuel ratio measurement in ITER experiments
Proposal for a neutron spectrometry system for the International Thermonuclear Experimental Reactor
Design consideration for high-energy-resolution neutron spectrometer based on associated particle detection using proton recoil telescope and time-of-flight technique for ITER
Journal Article
·
Sun Oct 15 00:00:00 EDT 2006
· Review of Scientific Instruments
·
OSTI ID:20861262
Proposal for a neutron spectrometry system for the International Thermonuclear Experimental Reactor
Journal Article
·
Sat Feb 29 23:00:00 EST 1992
· Fusion Technology; (United States)
·
OSTI ID:5519517
Design consideration for high-energy-resolution neutron spectrometer based on associated particle detection using proton recoil telescope and time-of-flight technique for ITER
Journal Article
·
Sun Oct 15 00:00:00 EDT 2006
· Review of Scientific Instruments
·
OSTI ID:20861240