Impact of the temperature dependency of fiberglass insulation R-value on cooling energy use in buildings

Conference ·
OSTI ID:451183

Building energy models usually employ a constant, room-temperature-measured value for the thermal resistance of fiberglass roof insulation. In summer, however, the mean temperature of roof insulation can rise significantly above room temperature, lowering the insulation`s thermal resistance by 10% to 20%. Though the temperature dependence of the thermal resistance of porous materials like fiberglass has been extensively studied, it is difficult to theoretically predict the variation with temperature of a particular fiberglass blanket, from first principles. Heat transfer within fiberglass is complicated by the presence of three significant mechanisms - conduction through air, conduction through the glass matrix, and radiative exchange within the matrix - and a complex, unknown internal geometry. Purely theoretical models of fiberglass heat transfer assume highly simplified matrix structures and require typically-unavailable information about the fiberglass, such as its optical properties. There is also a dearth of useful experimental data. While the thermal resistances of many individual fiberglass samples have been measured, there is only one practical published table of thermal resistance vs. both temperature and density. Data from this table was incorporated in the DOE-2 building energy model. DOE-2 was used to simulate the roof surface temperature, roof heat flux, and cooling energy consumption of a school bungalow whose temperature and energy use had been monitored in 1992. The DOE-2 predictions made with and without temperature variation of thermal conductivity were compared to measured values. Simulations were also run for a typical office building. Annual cooling energy loads and annual peak hourly cooling powers were calculated for the office building using both fixed and variable thermal conductivities, and using five different climates. The decrease in the R-value of the office building`s roof led to a 2% to 4% increase in annual cooling energy load.

Research Organization:
Lawrence Berkeley Lab., CA (United States)
Sponsoring Organization:
USDOE Assistant Secretary for Energy Efficiency and Renewable Energy, Washington, DC (United States)
DOE Contract Number:
AC03-76SF00098
OSTI ID:
451183
Report Number(s):
LBL--38678; CONF-9608106--17; ON: DE97003822
Country of Publication:
United States
Language:
English

Similar Records

Trade-off between cool roofs and attic insulation in new single-family residential buildings
Conference · Wed Jul 01 00:00:00 EDT 1998 · OSTI ID:20001983

Good roofs save energy-NRCA energy manual
Book · Thu Sep 01 00:00:00 EDT 1977 · OSTI ID:6068427

Modeling the effects of reflective roofing
Conference · Thu Aug 01 00:00:00 EDT 1996 · OSTI ID:453493