Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Sandia Pulsed Reactor III (SPR III): predicted performance characteristics

Technical Report ·
OSTI ID:4419615

The predicted performance characteristics of the Sandia Pulsed Reactor III (SPR III are presented. The principal design criteria are to provide an irradiation cavity ~18 cm in diameter and ~40 cm long, and a fluence of 6 x 10/ sup 14/ nvt (near-fission spectrum) neutrons in a single pulse with a width, at half maximum intensity, of less than 60 microseconds. 9 references. (auth)

Research Organization:
Sandia Labs., Albuquerque, N.Mex. (USA)
DOE Contract Number:
AT(29-1)-789
NSA Number:
NSA-29-009406
OSTI ID:
4419615
Report Number(s):
SLA--73-812
Country of Publication:
United States
Language:
English