G-value for the ferrous sulphate dosemeter for radiation from californium- 252
Journal Article
·
· Phys. Med. Biol., v. 18, no. 6, pp. 800-807
The FeSO/sub 4/ G-value for the mixed neutron and gamma -radiation from californium-252 has been measured experimentally using ionization dosimetry. A value of 9.9 plus or minus 0.7 was obtained for irradiations in air ( gamma - component 31%) and 10.1 plus or minus 0.8 in water, a scattering medium, ( gamma -component 43%). Calculated G-values for the neutron component alone were consistent with theoretical predictions. ( auth)